Turnkey container data center

Don't build your data center. Take delivery of it.

DMT Modular builds it, HyperDC Data installs power and cooling, TopTel brings the IT infrastructure with Gigabyte, Sangfor, Extreme Networks and TerraMaster, and QPS designs, installs and operates it. You sign a single contract: with TopTel.

  1. Manufacturing

    DMT Modular, Ankara

  2. Power and cooling

    HyperDC Data

  3. Technology

    TopTel, 7 global brands

  4. Engineering

    QPS, design and commissioning

  5. Operations

    QPS, monitoring and maintenance

Look inside

Layer by layer, one system.

As you scroll, the 40 ft container opens up layer by layer. Every layer has an owner.

Axonometric cutaway of a 40 ft container data center. Enterprise view: On the left, the power room (UPS, batteries, distribution panel, suppression gas cylinders); in the middle, a single row of IT racks with in-row cooling units and hot aisle containment; on the right, the control room with a DCIM screen and an access-controlled door; outdoor units outside. Cable trays and smoke detectors on the ceiling. Length 12.19 m (40 ft). AI view: On the left, the power room (UPS, batteries, distribution panel, suppression gas cylinders); in the middle, the CDU and liquid-cooled GPU racks, with the DLC manifold above the racks and hot aisle containment; on the right, the control room with a DCIM screen; dry coolers outside. Length 12.19 m (40 ft).

40 ft · 12.19 m

It arrives as a closed module.

Scroll down: the container opens and the four layers come forward one by one.

1 / 4 · DMT Modular

Structure and shell

Steel shell and corner castings, raised floor, cable trays and physical access control.Steel shell and corner castings, raised floor, cable trays and physical access control.

  • Steel container shell and roof
  • Corner castings
  • Raised floor
  • Cable trays
  • Access control (card reader)

2 / 4 · HyperDC Data

Power, cooling and fire protection

UPS, batteries and distribution panel; in-row cooling units and outdoor units; smoke detection and gas suppression.UPS, batteries and distribution panel; DLC manifold, CDU and outdoor dry coolers; smoke detection and gas suppression.

  • UPS
  • Battery cabinets
  • Distribution panel
  • In-row cooling units
  • CDU (coolant distribution unit)
  • DLC manifold: supply and return lines
  • Outdoor units
  • Dry coolers
  • Smoke detectors
  • Suppression gas cylinders and distribution piping

3 / 4 · TopTel · Gigabyte, Sangfor, Extreme Networks, TerraMaster

IT racks

Server, network, platform and storage racks in a single row, with hot aisle containment.Liquid-cooled GPU server racks, networking and storage, with hot aisle containment.

  • Rack row: servers, networking and storage
  • Rack row: GPU servers, networking and storage
  • Hot aisle containment

4 / 4 · QPS

Monitoring and operations

Environmental monitoring from the DCIM screen; remote monitoring, periodic maintenance and optional managed operations.Environmental monitoring from the DCIM screen; remote monitoring, periodic maintenance and optional managed operations.

  • DCIM monitoring screen and control desk

One project · one contract

Four disciplines, one point of contact: TopTel.

DMT Modular brings the structure, HyperDC Data the power and cooling, TopTel the IT infrastructure; QPS designs, installs and operates.

Structure and shellDMT Modular

  • Steel container shell and roof
  • Corner castings
  • Raised floor
  • Cable trays
  • Access control (card reader)

Power, cooling and fire protectionHyperDC Data

  • UPS
  • Battery cabinets
  • Distribution panel
  • In-row cooling units
  • CDU (coolant distribution unit)
  • DLC manifold: supply and return lines
  • Outdoor units
  • Dry coolers
  • Smoke detectors
  • Suppression gas cylinders and distribution piping

IT racksTopTel · Gigabyte, Sangfor, Extreme Networks, TerraMaster

  • Rack row: servers, networking and storage
  • Rack row: GPU servers, networking and storage
  • Hot aisle containment

Monitoring and operationsQPS

  • DCIM monitoring screen and control desk

When a container?

A data center that comes to where you need it, instead of waiting for a building

Your next-generation GPU servers don't fit in your server room

In Gigabyte's HGX B300-based GIGAPOD racks, power per rack reaches 66–70 kW with air cooling and 109 kW with liquid cooling. Traditional server rooms are designed for a fraction of that per rack. A module designed from the ground up for high density and liquid cooling is often faster and more predictable than converting an existing building.

GIGAPOD

You don't have time to build a data center

Planning and constructing a data center building is often measured in years. With a container, manufacturing and hardware procurement run in parallel; the work on site comes down to the foundation and connections.

Compute belongs next to the energy

A power plant, a solar farm or an organized industrial zone: a module installed where the electricity is generated is the shortest path to turning energy directly into compute.

Your site is remote and harsh

A mine, a construction site, a port or a border region. Arriving with its own shell, cooling, fire protection and access control, the module runs independently of site conditions.

You need a second site for disaster recovery

A backup site, geographically distant from your main data center and set up quickly. With Sangfor HCI replication, your workloads are decoupled from regional risks such as earthquakes.

What's inside?

Not a box, but a working system

The container is only the shell; its value is the system running inside. We add the structure as a fifth layer to the four validated layers of GigaX and deliver it all in a single project.

LayerWhat it includesProvided by
Structure and shellSteel construction, thermal and fire insulation, raised floor, cable routes, physical access control, anchoring and fastening per the Turkish Building Earthquake Code (TBDY 2018)DMT Modular
Power, cooling and fire protectionUPS and power distribution, air or liquid cooling, aspirating early smoke detection, FK-5-1-12 or inert gas suppression, environmental monitoring with DCIMHyperDC Data
ComputeData-center-class servers, from general-purpose servers to NVIDIA HGX B300 and H200 GPU systemsGigabyte
Network backboneData center backbone and centralized network management with Platform ONEExtreme Networks
Platform and securityHCI virtualization, replication and NGAF next-generation firewallSangfor
Storage and backupNAS storage and backup targetTerraMaster
OperationsRemote monitoring, periodic maintenance, incident management and optional fully managed operationsQPS

IT components are supplied through TopTel as authorized distributor; facility infrastructure is supplied by HyperDC Data. Project responsibility and the single contract sit with TopTel.

Starting points

Three packages, each sized to your needs

Every project is designed around its own load, site and criticality level. These three packages show where we start the conversation.

Edge

A compact module for factories, mines, construction sites, branches and power plant control points.

Container
10 ft or 20 ft
IT racks
1–4
Power per rack
3–10 kW
Cooling
Room-level precision air conditioning (DX)
Redundancy
N or N+1
Typical infrastructure
Sangfor HCI (2–3 nodes), Extreme Networks, TerraMaster backup

Enterprise

For organizations that want to expand their main data center or set up a geographically separate backup site.

Container
20 ft or 40 ft
IT racks
4–10
Power per rack
5–15 kW
Cooling
In-row cooling and aisle containment
Redundancy
N+1, or 2N if required
Typical infrastructure
Gigabyte servers, Sangfor HCI cluster and NGAF, Extreme backbone, TerraMaster

AI and high density

A liquid-cooling-ready module for model training, inference and anyone looking to offer GPU services.

Container
40 ft; for large deployments, an IT module plus a separate power/cooling moduleFor large deployments, HyperDC Data's 0.5–1 MW prefabricated power and cooling blocks.
IT racks
2–10
Power per rack
66–70 kW with air-cooled HGX, up to 110 kW with liquid-cooled HGX
Cooling
Active rear-door heat exchanger (RDHx) or direct liquid cooling (DLC)
Redundancy
N+1
Typical infrastructure
Gigabyte HGX B300 / H200 servers, GIGAPOD architecture, high-speed networking, TerraMaster

Values are typical ranges. Exact capacity is determined after discovery and design.

Preliminary sizing

Estimate your capacity

If you know what you'll deploy, see in seconds how much power, how many racks and what cooling you need.

GPU server cooling

Determines rack density and cooling type

About 15 kW per server (8U, 4 per rack)

About 10.2 kW per server (8U, 4 per rack)

About 0.8 kW per server

About 0.5 kW per unit

20%

Capacity reserved for future expansion

89.8kW

Total IT load, including growth headroom

Grid connection (peak, rough)
≈ 139 kW
Target annual PUE
1.35–1.45
IT racks
4
Densest rack
≈ 66 kW
Recommended container
1 × 40 ft container
Recommended cooling
Active rear-door heat exchanger (RDHx)
Starting package
AI and high density

This is a preliminary sizing based on typical manufacturer figures. For air-cooled 8-GPU servers, it assumes 4 servers per rack and about 6 kW of additional load per rack; for liquid-cooled ones, 8 servers per rack. Standard racks are assumed to hold 16 units; for deployments with GPUs or more than one rack, 1 extra rack and about 3 kW are added for networking and management. The grid connection is calculated with a rough peak factor that covers the cooling load on the hottest day and distribution losses; annual PUE is lower than this. The final design is done by QPS engineers.

Process

Six steps from discovery to operations

Every step has a clear owner and a defined output. You have one point of contact from start to finish.

  1. Discovery and preliminary sizing

    Together we clarify your needs, your site and your power situation. The outcome is a preliminary sizing and a budget range.

    QPS

  2. Design and a single proposal

    The architecture is designed; structure, infrastructure and IT come together in one proposal and one contract.

    QPS, HyperDC Data and TopTel

  3. Manufacturing and procurement

    While the container is being built, procurement of servers, networking and storage starts in parallel. This shortens the timeline for long-lead GPU systems.

    DMT Modular, HyperDC Data and TopTel

  4. Factory acceptance test

    Power, cooling and IT systems are tested together before shipment. What arrives on site is a proven system, not a surprise.

    DMT Modular, HyperDC Data and QPS

  5. Site installation and commissioning

    The module is placed on the prepared foundation, power and network connections are made, and it is handed over after the site acceptance test.

    QPS and HyperDC Data

  6. Operations

    If you wish, monitoring, maintenance and operations are handed over to QPS. You focus on your business; the infrastructure is on us.

    QPS; facility infrastructure maintenance by HyperDC Data

Scope

What we deliver, and what you prepare

The limits of turnkey are written down up front. No surprises at handover.

We deliver

  • Architecture design and engineering
  • Container manufacturing and shipment to site
  • UPS, power distribution and cooling
  • Fire detection and suppression, access control
  • IT infrastructure: servers, networking, platform, security, storage
  • Anchoring and fastening design per the Turkish Building Earthquake Code (TBDY 2018)
  • Installation, commissioning and acceptance tests
  • Training and handover documentation
  • Optional managed operations

You prepare

  • The site and foundation for the container
  • Power connection: the grid or your own power plant
  • Internet and fiber connectivity
  • Zoning, building and energy permits

We provide the technical information you need for your permit applications (dimensions, weight, power requirements).

Why us?

One contract, four disciplines

The teams that build the container, install power and cooling, distribute the technology that goes inside, and install and operate the system sit at the same table. No intermediaries, no handed-off responsibility, no lost time.

Builds

DMT Modular

  • 35,000 m² manufacturing facility in Ankara
  • TÜV Austria EN 1090 and ISO 14001 certified manufacturing
  • Modular building deliveries from Türkiye to Europe

Power and cooling

HyperDC Data

  • UPS and power distribution
  • Precision and high-density cooling, fire protection
  • Prefabricated power/cooling blocks and a mobile power container
  • Facility infrastructure maintenance and service
  • Ataşehir / Istanbul

Equips

TopTel

  • Authorized distributor in Türkiye for 7 global brands
  • Over 20 years of experience, a network of 500+ partners
  • One contract, one point of contact for warranty and support

Installs and operates

QPS

  • TopTel's engineering arm
  • Design, commissioning and managed operations
  • Architect of GigaX integrated systems

The redundancy level (N, N+1 or 2N) is set up front based on your project's criticality. If you have a certification target, the design is built around it; if not, power, cooling and monitoring are still designed on the principles of continuous operation.

FAQ

Common questions about container data centers

How long does it take to deliver a container data center?

Two things mostly set the timeline: the infrastructure scope and the lead time for IT hardware. Because container manufacturing and hardware procurement run in parallel, the total time is close to the longer of the two. For high-demand GPU systems, lead time can be the deciding factor; after discovery, we share a dated project plan.

Can we move our existing servers into the container?

Yes. The container can be designed to host your existing hardware as well. For new infrastructure, we recommend the GigaX architecture, validated with brands from the TopTel portfolio.

When is liquid cooling needed?

As power per rack rises, air cooling falls short. Roughly, in-row cooling is sufficient up to 30 kW and an active rear-door heat exchanger between 30 and 80 kW; at higher densities, or with liquid-cooled servers, direct liquid cooling (DLC) is required. HGX B300 comes in both air-cooled (8U) and liquid-cooled (4U) options; the choice determines rack density and container design. The calculator uses the same thresholds.

Can the container be expanded or relocated later?

Yes. Thanks to the modular design, new modules can be added as your needs grow. When necessary, a module is moved to another site and recommissioned.

Who is responsible for the power connection and permits?

The site, the power connection, and zoning, building and energy permits are your responsibility. We provide the technical information needed for the permit process (dimensions, weight, power requirements).

Who is our point of contact for warranty and support?

Your single point of contact is TopTel. IT components are delivered with manufacturer warranties; support and operations run through QPS. Maintenance and service of the facility infrastructure (power, cooling and fire systems) are carried out by HyperDC Data.

Discovery call

Let's talk about your site and your needs

It doesn't matter how much you already know. Tell us what you know; we'll work out the rest together during discovery.

Within two business days, a QPS engineer will get back to you and schedule a discovery call.

+90 (216) 469 1750info@toptel.com.trGülağacı Sok. No:22, Küçükbakkalköy, 34750 Ataşehir / İstanbul