Advanced Cooling
Gigabyte Enterprise · Advanced Cooling
Gigabyte G2L5-DR4-L08
HPC/AI Server - AMD EPYC™ 9006 SP7 Server Processors - 2U DP NVIDIA HGX™ Rubin NVL8 DLC
The Gigabyte G2L5-DR4-L08 is one of the G2L5 series 2U advanced-cooling servers. It comes with 2 × AMD EPYC processors, 32 DIMM slots, 8 x E1.S drive bays, and direct liquid cooling (DLC). It supports 8 × NVIDIA HGX Rubin NVL8 GPUs. As the authorized distributor of Gigabyte Enterprise in Türkiye, TopTel delivers this model with project-specific configuration, local stock and QPS deployment support.

Highlights
- Liquid-cooled NVIDIA HGX™ Rubin NVL8
- CPU+GPU direct liquid cooling solution with leak detection
- 8 x 800 Gb/s OSFP InfiniBand or Ethernet GPU networking ports via 8 x single-port NVIDIA ConnectX®-9 VPI
- 3.6 TB/s GPU-to-GPU bandwidth with NVIDIA NVLink™ and NVIDIA NVLink™ Switch
- Dual AMD EPYC™ 9006 SP7 Server processors
- 16-Channel liquid-cooled DDR5 RDIMM/MRDIMM per CPU with 32 x DIMMs
- 1 x 1 Gb/s LAN ports via Intel® I210-AT
- 2 x M.2 slots with PCIe Gen4 x4
- 8 x liquid-cooled E1.S Gen6 NVMe hot-swap bays
- 1 x liquid-cooled FHFL PCIe x16 slot with Gen6 x16 lanes for NVIDIA BlueField®-4 DPU
- 54 V DC Bus Bar power solution
Technical Specifications
| Form Factor | 2U |
| CPU Series | AMD EPYC |
| CPU Type | AMD EPYC 9006 SP7 |
| CPUs | 2 |
| CPU Socket | Socket SP7 |
| Chipset | AMD® SoC |
| DIMM Slots | 32 |
| Drive Bays | 8 x E1.S |
| GPU Type | NVIDIA HGX Rubin NVL8 |
| GPUs | 8 |
| LAN | 1 × 1 Gb/s |
| Cooling Type | Direct Liquid Cooling |
| PSU | 54 V bus bar |
| Platform | x86 Server |
| Application | AI Platform, High-Performance Computing Server, AI Training Server, AI Inference Server |
| Processor Vendor | AMD |
| Series | G Series |
| Max TDP (cTDP) | 600 W |
| GPU Series | NVIDIA HGX |
Use cases
- High-density AI racks
- High-density HPC clusters
- PUE reduction projects
Sourcing the G2L5-DR4-L08 from TopTel
- Project-based ordering, configuration and delivery planning
- Project-specific configuration: memory, disk, GPU, NIC selection
- Deployment with QPS engineering, BIOS/BMC configuration and commissioning
- On-site service and RMA management in Turkey
- Validated with Sangfor HCI as part of the GigaX integrated system
Frequently asked questions
Can DLC be added to an existing data center?
Yes, with CDU and manifold infrastructure; TopTel/QPS provides feasibility support.
Get a quote for the G2L5-DR4-L08
We respond within 1 business day with configuration, stock and lead time.