Skip to content
TopTel
Advanced Cooling

Gigabyte Enterprise · Advanced Cooling

Gigabyte G4L3-SD1-LAX5

HPC/AI Server - 5th/4th Gen Intel® Xeon® Scalable Processors - 4U DP NVIDIA HGX™ B200 DLC

The Gigabyte G4L3-SD1-LAX5 is one of the G4L3 series 4U advanced-cooling servers. It comes with 2 × Intel Xeon Scalable processors, 32 DIMM slots, 8 x 2.5" drive bays, and direct liquid cooling (DLC). It supports 8 × NVIDIA HGX B200 GPUs. As the authorized distributor of Gigabyte Enterprise in Türkiye, TopTel delivers this model with project-specific configuration, local stock and QPS deployment support.

Gigabyte G4L3-SD1-LAX5 Advanced Cooling

Highlights

  • Liquid-cooled NVIDIA HGX™ B200
  • CPU+GPU direct liquid cooling solution with leak detection
  • 1.8 TB/s GPU-to-GPU bandwidth with NVIDIA NVLink™ and NVSwitch™
  • Dual 5th/4th Gen Intel® Xeon® Scalable processors
  • Dual Intel® Xeon® CPU Max Series
  • 8-Channel DDR5 RDIMM per CPU with 32 x DIMMs
  • Compatible with NVIDIA® BlueField®-3 DPU and NVIDIA ConnectX®-7 NIC
  • 2 x 10 Gb/s LAN ports via Intel® X710-AT2
  • 2 x M.2 slots with PCIe Gen3 x2 and x1
  • 8 x 2.5" Gen5 NVMe/SATA hot-swap bays
  • 4 x FHHL dual-slot PCIe x16 slots with Gen5 x16 lanes
  • 8 x FHHL single-slot PCIe x16 slots with Gen5 x16 lanes
  • 4+4 3000 W 80 PLUS Titanium redundant power supplies

Technical Specifications

Form Factor4U
CPU SeriesIntel Xeon Scalable
CPU Type4th Gen Intel Xeon Scalable, Intel Xeon CPU Max Series, 5th Gen Intel Xeon Scalable
CPUs2
CPU SocketLGA 4677
ChipsetIntel® C741
DIMM Slots32
Drive Bays8 x 2.5"
GPU TypeNVIDIA HGX B200
GPUs8
LAN2 × 10 Gb/s
Cooling TypeDirect Liquid Cooling
PSU8 x 3000 W
Platformx86 Server
ApplicationAI Platform, High-Performance Computing Server, AI Training Server, AI Inference Server
Processor VendorIntel
SeriesG Series
Max TDP (cTDP)350 W
GPU SeriesNVIDIA HGX

Use cases

  • High-density AI racks
  • High-density HPC clusters
  • PUE reduction projects

Sourcing the G4L3-SD1-LAX5 from TopTel

  • Project-based ordering, configuration and delivery planning
  • Project-specific configuration: memory, disk, GPU, NIC selection
  • Deployment with QPS engineering, BIOS/BMC configuration and commissioning
  • On-site service and RMA management in Turkey
  • Validated with Sangfor HCI as part of the GigaX integrated system

Frequently asked questions

Can DLC be added to an existing data center?

Yes, with CDU and manifold infrastructure; TopTel/QPS provides feasibility support.

Get a quote for the G4L3-SD1-LAX5

We respond within 1 business day with configuration, stock and lead time.

Request a Quote