Skip to content
TopTel
Advanced Cooling

Gigabyte Enterprise · Advanced Cooling

Gigabyte G4L4-AD3-LAX7

HPC/AI Server - Intel® Xeon® 6900E+/6900-Series Processors - 4U, DP, NVIDIA HGX™ B300, DLC

The Gigabyte G4L4-AD3-LAX7 is one of the G4L4 series 4U advanced-cooling servers. It comes with 2 × Intel Xeon 6 processors, 24 DIMM slots, 8 x 2.5" drive bays, and direct liquid cooling (DLC). It supports 8 × NVIDIA HGX B300 GPUs. As the authorized distributor of Gigabyte Enterprise in Türkiye, TopTel delivers this model with project-specific configuration, local stock and QPS deployment support.

Gigabyte G4L4-AD3-LAX7 Advanced Cooling

Highlights

  • Liquid-cooled NVIDIA HGX™ B300
  • Integrated-manifold DLC solution with leak detection
  • 8 x 800 Gb/s OSFP XDR InfiniBand or dual 400 Gb/s Ethernet GPU networking ports via onboard NVIDIA ConnectX®-8 SuperNIC™
  • 1.8 TB/s GPU-to-GPU bandwidth with NVIDIA NVLink™ and NVIDIA NVLink™ Switch
  • Dual Intel® Xeon® 6900E+/6900-series processors
  • 12-Channel liquid-cooled DDR5 RDIMM/MRDIMM per CPU with 24 x DIMMs
  • Compatible with NVIDIA BlueField®-3 DPUs
  • 2 x 10 Gb/s LAN ports via Intel® X710-AT2
  • 2 x M.2 slots with PCIe Gen5 x4 and x2
  • 8 x 2.5" Gen5 NVMe hot-swap bays
  • 4 x FHHL PCIe x16 slots with Gen5 x16 lanes
  • 5+5 3000 W 80 PLUS Titanium redundant power supplies

Technical Specifications

Form Factor4U
CPU SeriesIntel Xeon 6, Intel Xeon 6+
CPU TypeIntel Xeon 6900 Series, Intel Xeon 6900E+
CPUs2
CPU SocketLGA 7529
ChipsetIntel® SoC
DIMM Slots24
Drive Bays8 x 2.5"
GPU TypeNVIDIA HGX B300
GPUs8
LAN2 × 10 Gb/s
Cooling TypeDirect Liquid Cooling
PSU10 x 3000 W
Platformx86 Server
ApplicationAI Platform, High-Performance Computing Server, AI Training Server, AI Inference Server
Processor VendorIntel
SeriesG Series
Max TDP (cTDP)550 W
GPU SeriesNVIDIA HGX

Use cases

  • High-density AI racks
  • High-density HPC clusters
  • PUE reduction projects

Sourcing the G4L4-AD3-LAX7 from TopTel

  • Project-based ordering, configuration and delivery planning
  • Project-specific configuration: memory, disk, GPU, NIC selection
  • Deployment with QPS engineering, BIOS/BMC configuration and commissioning
  • On-site service and RMA management in Turkey
  • Validated with Sangfor HCI as part of the GigaX integrated system

Frequently asked questions

Can DLC be added to an existing data center?

Yes, with CDU and manifold infrastructure; TopTel/QPS provides feasibility support.

Get a quote for the G4L4-AD3-LAX7

We respond within 1 business day with configuration, stock and lead time.